Email: sales@yosemitech.com

Y4003 Multi-parameter Sonde for Deep Water

Yosemitech Y4003 Multiparameter Sonde designed for use in deep water. It features a robust structural design and a self-developed titanium alloy water-tight connector, making it suitable for deep water, well, marine, and other challenging working conditions.


  • Model number: Y4003
  • Power: 0.8W(non wiping), 2W(wiping)
  • Dimension: Φ84mm*476mm
  • Customize: OEM, ODM, details contact: sales@yosemitech.com
  • Place of Origin: China
Overview

Yosemitech Y4003 deep-water multi-parameter sonde features a robust structural design, an in-house developed titanium (Ti) waterproof connector, and is specifically engineered for deep water/well, marine, and other demanding working conditions. The main unit can connect up to six probes, with options including DO, pH, ORP, conductivity (salinity), turbidity, chlorophyll, BGA, OIW, and depth sensors, which can be freely selected based on application requirements. All probes are constructed from titanium, ensuring excellent corrosion resistance.

The Y4003 is equipped with a self-cleaning brush that effectively cleans the measurement surface, removes bubbles, prevents microbial attachment, and ensures stable performance under underwater pressures of up to 200 meters. This makes it suitable for monitoring needs in deepwater lakes, oceanic environments, underground drilling, harsh wastewater treatment, and other mid-to-deep water scenarios.

Features

- RS485 output with standard MODBUS protocol, facilitating seamless integration with data acquisition platforms and water quality automatic monitoring stations.
- The main body includes six standardized probe interfaces and a central interface for the cleaning brush, enabling flexible plug-and-play functionality with Yosemitech probes and automatic identification.
- All calibration parameters are stored within individual sensors, allowing for convenient on-site replacement, calibration, and maintenance.
- The configured probes are all made of titanium, providing high-pressure resistance and reliable operation at depths of up to 200 meters underwater.

Specifications

NameDeep Water Multi-parameter Sonde
ModelY4003
Measuring depth0-200m
Main body informationconnect up to 6 probes, 1 central cleaning brush
SizeΦ84mm*544.4mm
Operating temperature0-50℃
Calibration dataThe calibration data is stored within the probe. The probe can be removed for direct calibration.
OutputRS-485 output, MODBUS protocol
Brush controlThe default cleaning frequency is once every 30 minutes. The cleaning interval can be set.
Full load power consumption0.8W(non-wiping), 2W(wiping);DC 12-24V, ≥1A
IP rangeIP68
Weight3.25kg(main body+6 probes)
Status alertPower supply abnormal alarm, communication abnormal alarm, cleaning brush abnormal alarm
Cable lengthWith waterproof connectors, 30 meters (default), customizable
MaterialPVC, Ti, anti-fouling copper
SensorModelRangeAccuracy
DOY504-D0-50mg/L or 0-500%saturation0-20mg/L:±1%or±0.2mg/L
>20mg/L:±5%or±0.6mg/L
TURY510-D0-1000NTU or 0-4000NTU±5%or0.3NTU,take the bigger one
Conductivity
Salinity
Y523-Dconductivity:0-200mS/cm
(0-2mS/cm、2-20mS/cm、20-200mS/cm)
±1%or0.01mS/cm,take the bigger one
salinity:0-175ppt±1ppt
TDS:0-128000mg/L/
OIWY616-D0-50ppm or 0-150ppmLinearity:R²>0.999
pHY532-D0-14 pH±0.02 pH
ORPY533-D﹣1999-1999mV±20mV
CHLY515-D0-500μg/L±5% or 0.5μg/L,take the bigger one
BGAY613-D0 - 300,000 cells/mL
(can be set at 0 - 2,000,000 cells/mL)
Linearity:R²>0.999
DepthY700-D0m-2m...200m<0.1% FS

What's In The Box

- Multiparameter Sonde
- 30m Cable(default), Customizable
- User Manual
- Delivery Inspection Report
- Other Accessories

Applications

Oceanographic Research:

Marine Ecosystem Studies: Measure parameters such as temperature, salinity, dissolved oxygen, pH, turbidity, and chlorophyll to understand marine ecosystems' health and dynamics.

Climate Change Research: Track changes in oceanographic conditions over time to study the impacts of climate change on marine environments.

Deep-Sea Exploration: Collect data from deep-sea environments to discover new species and understand the geology and chemistry of the ocean floor.

Environmental Monitoring:

Pollution Detection: Monitor for pollutants like oil, heavy metals, and chemicals in deep water to detect and address pollution sources.

Water Quality Assessment: Continuously monitor water quality parameters to ensure the health of aquatic ecosystems and compliance with environmental regulations.

Harmful Algal Bloom (HAB) Monitoring: Detect and track harmful algal blooms that can affect marine life and human health.

Fisheries and Aquaculture:

Habitat Monitoring: Ensure optimal conditions for fish health and growth by monitoring parameters such as dissolved oxygen, temperature, and turbidity.

Resource Management: Use data to manage fish stocks and aquaculture operations more effectively, ensuring sustainable practices.

Hydrographic Surveys:

Mapping and Charting: Collect data for accurate mapping and charting of underwater features and seabed topography.

Subsea Infrastructure: Monitor conditions around subsea pipelines, cables, and other infrastructure to ensure their integrity and safety.

Deep Lake and Reservoir Studies:

Ecosystem Health: Study the health and dynamics of deep freshwater lakes and reservoirs by measuring key parameters.

Water Supply Management: Monitor water quality to manage and protect drinking water sources.

FAQS
What are Five Parameters of Conventional Water Quality?

pH: 

Changes in pH in surface water quality affect the ability of algae to take up oxygen and the sensitivity of animals to food intake.


Conductivity: 

mainly measures the electrical conductivity of water and monitors the total ion concentration in the water body. Contains a variety of chemicals, heavy metals, impurities and so on a variety of conductive material total.


Dissolved oxygen: 

DO in surface water in addition to the usual water sulfide, nitrite, ferrous ions and other reducing substances consumed, but also by the respiration of microorganisms in the water as well as organic matter in the water by the oxidative decomposition of aerobic microorganisms consumed. Dissolved oxygen is an important indicator for surface water monitoring, and is an indication of whether the water body has the ability to self-purify.


Turbidity: 

The turbidity value is a visual reflection of the turbidity of the water body. Turbidity is mainly caused by the insoluble substances in the water, insoluble substances including sediment suspended in the water, corrosive substances, planktonic algae and colloidal particles. Reducing turbidity also reduces bacteria, coliform bacteria, viruses, cryptosporidium, iron, manganese, etc. in the water.


Temperture: 

Changes in surface water temperature can have a significant negative impact on aquatic wildlife, affecting biological growth and the rate at which fish and shrimp species feed, as well as the timing and efficiency of their reproduction.


Yosemitech Multi parameter Water Quality Sensor and Meter Types

Yosemitech supply two types of Multi parameter Water Quality Sensor and one type of Handheld Multi parameter Water Quality Meter. Our multiparameter water quality sensor & meter price is affordable with high quality.


Multi-parameter Water Quality Sonde

1. Online water quality analysis and monitoring of surface water and groundwater quality of river section, river, reservoir and so on. 

2. Internet of things, intelligent agriculture, online aquaculture monitoring. 

3. Water Quality real-time monitoring, red tide monitoring and early warning, blue-green algae monitoring and early warning, sudden pollution accident early warning, surface water quality investigation. 

4. Research projects. Investigation of pollution sources in the estuary, temporal and spatial distribution of nitrogen and phosphorus in aquaculture area, continuous and automatic monitoring in coastal waters.



Video
Yosemitech Multi-parameter Meter Calibration Guide-Turbidity Sensor

Yosemitech Multi-parameter Meter Calibration Guide-CT Sensor

In this video, we will delve into the entire calibration process of Conductivity Sensor for Y4001 Handheld Meter. 

Calibration is a crucial step for ensuring the accuracy and reliability of sensor measurement data.

This video includes: 

Preparation: required tools and precautions. 

Step-by-step operation: from connecting the equipment to completing the calibration, hands-on instruction.

Yosemitech Multi-parameter Meter Calibration Guide-DO Sensor

2025 IE expo Guangzhou

Y4003 Online Multi-parameter Sonde for Deep Water

Y4003 multi-parameter sonde can operate stably at a depth of 200m  underwater. 

-Robust and pressure-resistant design, self-developed Ti waterproof connectors -6 sensor interfaces of uniform specifications and 1 central cleaning brush interface (optional DO, pH,ORP, conductivity/salinity, turbidity, chlorophyll, BGA,OIW, Depth probes etc. ). 

-All probes are made of Ti, pressure-resistant and corrosion-resistant. 

-It is utilized for the monitoring of water environments, including oceans, deep lakes, underground wells, and challenging wastewater systems. 

If you want to know more information or quotation, feel free to contact us!

Leave Your Message

Leave Your Message